Product Overview

Lixel L2 PRO, a highly integrated and lightweight handheld 3D reconstruction device. With the 3D real-time reconstruction algorithm, Lixel L2 PROcan directly obtain the true color point cloud. The results are calculated in real time and can be viewed and used immediately.

About Lixel L2 PRO

Operation

Battery installation

  1. Open the lever.
  2. Insert the battery into the bottom of the device along the guide dovetail slot. Ensure that the battery is inserted into the correct position.
  3. Press the lever back and lock the battery tightly.

Note: An unsecured battery may cause the device to slip.

Tripod Installation

The bottom of the battery has threaded holes. Screw the tripod in and place the device in a flat position.

Function Button

Note:

  1. Please put the device on the flat table before starting the scan. After starting the scan, the device can be moved for scanning only after the lidar rotates.
  2. It takes about 10 seconds to start scanning.
  3. During the scanning stop, if the indicator blinks green quickly, scanned files are being stored. If the power is off at this time, files may be lost or saved incompletely.
  4. After the scan is stopped, the waiting time for stored files may be long, it’s depending on the size of the scene being scanned.

Indicator Light Description

Data Copy Description

Use the USB cable that matches the device. Connect the device to the computer in standby mode and turn on the USB mode in the App. After identifying the device, the data can be copied.

Note:

  1. The USB mode is automatically disabled after a restart.
  2. After turning on the USB mode, you need to manually turn off the USB mode if you want to continue scanning without shutting down or power off.
  3. Using a non-standard USB cable may cause slow data copy. Or may cause forward insertion can be used, reverse insertion can not be used.

Battery

Use the standard charging cable and connect the charging adapter to the battery to charge the battery.

Charging time: about 2 hours. During the charging process, the indicator light will show the current electric quantity.

Please refer to the following table for details.

Maintenance

The storage status of the device is as shown in the figure below. After use, remove the battery and put it back into the storage box according to the figure.

Note: It is a precision device, not storing as required may cause damage to the device.

Matters needing attention

  1. Lixel L2 PRO is a precision device. Falling or being hit by external forces may damage the equipment and result in abnormal or inaccurate accuracy.
  2. When using a tripod, ensure that the tripod and the device are tightened to prevent the device from falling.
  3. Ensure that after Lixel L2 PRO is turned on, lidar rotation is not blocked by external forces.
  4. Lixel L2 PRO waterproof grade is IP54, do not use in the environment beyond this protection grade. Use a soft dry cloth or standard cleaning cloth to clean the device. Keep the lidar and the camera clean, do not touch it directly.
  5. The device will generate heat during use. Please do not touch the fuselage to avoid burns.
  6. Do not cover or touch the heat sink during use. The device may automatically shut down when the temperature is too high.

Appendix